Símbolo Fondo Science

Contacte para más información en el teléfono +34 629 829 605

Revista del Pie y Tobillo

Sociedad Española de Medicina y Cirugía del Pie y Tobillo

ISSN online: 2173-2949
ISSN impreso: 1697-2198
Vol. 23. Núm. 1. Mayo 2009
(sin asignar)
Recibido: 10 de noviembre de 2008
Aceptado: mayo de 2009
Originales

Osteosíntesis percutánea con tornillos canulados en fracturas de metáfisis tibial distal

Percutaneous osteosynthesis with cannulated screws in distal tibial metaphysis fractures

Rev Pie Tobillo. 2009;23(1):19-24

Resumen: 

Objetivo: evaluar el resultado de la osteosíntesis percutánea mediante tornillos canulados de 7,3 mm en pacientes con fractur de la metáfisis tibial distal extraarticular, tratados en el Hospital 12 de Octubre entre los años 1999 y 2007.

Material y método: estudio retrospectivo de 15 pacientes, 10 varones y 5 mujeres, con una edad media de 49,2 años. Cinco pacientes sufrieron f 43 A1; 6 pacientes, fractura 43 A2, y 4 pacientes, fractura 43 A3. Hubo 7 casos con fractura de peroné asociada y 3 con fracturas abiertas. Ocho de los casos fueron intervenidos el mismo día de su ingreso, mientras que en los 7 restantes la cirugía se demoró una media de 4 días (2-7 días). El seguimiento mínimo de los pacientes fue de 12 meses (media: 58 meses; rango: 12- 108 meses). El tiempo medio hasta la consolidación fue de 14,7 semanas (rango: 8-24).

Resultado: valoración clínico-funcional según la escala de AOFAS para tobillo y retropié. Resultados excelentes en 9 pacientes (60%), buenos en 4 pacientes (27%), regulares en 2 pacientes (13%). Ausencia de casos con deformidad angular o rotacional mayor de 5 grados, y de acortamientos mayores de 1 cm. No se registraron complicaciones infecciosas profundas ni en partes blandas.

Conclusión la utilización de tornillos canulados es una alternativa terapéutica muy válida, para el tratamiento de este tipo de fracturas, pues minimiza el daño de las partes blandas y tiene un bajo coste.

Abstract: 

Aims and objetives: to assess the results of percutaneous osteosynthesis using 7.3-mm cannulated screws in patients with extra-articular distal tibial metaphysis fractures treated at the “12 de Octubre” University Hospital (Madrid, Spain) between 1999 and 2007.

Material and methods: retrospective study of 15 patients (10 males, 5 females) with a mean age of 49.2 years. Five patients had an 43 A1 fracture, six had a 43 A2 one and four had a 43 A3 one. Associated fibular fracture was present in seven cases, and there were three cases with open fractures. Eight cases underwent surgery on the same day of their admission, while in the remaining seven cases surgery was postponed by a mean of 4 (2-7) d The minimum follow-up of the patients was 12 months (mean, 5 months; range, 12-108 months). The mean time to consolidation was 14.7 weeks (range, 8-24 weeks).

Results: clinico-functional assessment using the AOFAS scoring scale for ankle and hindfoot. Excellent results in nine (60%) patients, good results in four (27%), and average in two (13%). There were no cases with angular or rotational deformity greater than 5o, nos of shortenings greater than 1 cm. There were no deep nor soft tissue infectious complications.

Conclusions: the use of cannulated screws is a highly valid therapeutic alternative for the surgical management of this type of fractures; it minimizes soft tissue damage and has a low cost.

Cita bibliográfica

Sánchez Morata EJ, Guerra Vélez P, Cano Egea JM, García Fernández D, Sanz Hospital FJ, Coello Nogués AOsteosíntesis percutánea con tornillos canulados en fracturas de metáfisis tibial distal. Rev Pie Tobillo. 2009;23(1):19-24. doi: (sin asignar)

Descargar artículo: 

Icono PDF rpt.2301.fs090503-osteosintesis-percutanea-con-tornillos-canulados.pdf

Licencia: 

Este contenido es de acceso abierto (Open-Access) y se ha distribuido bajo los términos de la licencia Creative Commons CC BY-NC-ND (Reconocimiento-NoComercial-SinObraDerivada 4.0 Internacional) que permite usar, distribuir y reproducir en cualquier medio siempre que se citen a los autores y no se utilice para fines comerciales ni para hacer obras derivadas.